Residual Current Circuit Breakers and RCBO

Residual Current Circuit Breakers and RCBO

Residual current circuit breakers (RCCBs) protect against electric shock and fire by detecting even small earth leakage currents — through a person, deteriorated insulation, or a damaged appliance — and disconnecting the circuit within milliseconds. RCBOs combine residual current protection with overload and short-circuit protection in a single DIN rail module, saving panel space and giving each circuit independent fault isolation. We stock Schneider Electric Acti9 RCCBs and RCBOs — 2P and 4P; sensitivity from 10 to 300 mA; Type AC, A, B and selective variants for every application from residential distribution boards to industrial main panels. Engineering support available for project specification.

Residual Current Circuit Breakers and RCBO
Manufacturer
Nominal (A)
Number of poles
Range of product
Rated breaking capacity (kA)
Trip Sensitivity (mA)
Trip Sensitivity
Tripping characteristics
A9D31610
Code: A9D31610
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

72.39 EUR (w/o VAT)
A9D31616
Code: A9D31616
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

70.88 EUR (w/o VAT)
A9D31620
Code: A9D31620
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

48.86 EUR (w/o VAT)
A9Z65463
Code: A9Z65463
On site: 0 gab On site: 0 gab

Supplier:

504.91 EUR (w/o VAT)
A9R21425
Code: A9R21425
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

65.76 EUR (w/o VAT)
A9D32613
Code: A9D32613
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

81.42 EUR (w/o VAT)
A9D32616
Code: A9D32616
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

82.25 EUR (w/o VAT)
A9R44440
Code: A9R44440
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

54.21 EUR (w/o VAT)
A9R41440
Code: A9R41440
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

68.45 EUR (w/o VAT)
BC008203
Code: BC008203
On site: 0 gab On site: 0 gab

Supplier:

105.60 EUR (w/o VAT)
LC1DT25BL
Code: LC1DT25BL
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

61.33 EUR (w/o VAT)
A9D55610
Code: A9D55610
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

38.55 EUR (w/o VAT)
A9D55616
Code: A9D55616
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

67.20 EUR (w/o VAT)
AR002203
Code: AR002203
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

31.94 EUR (w/o VAT)
A9D56616
Code: A9D56616
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

78.32 EUR (w/o VAT)
AR052103
Code: AR052103
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

50.90 EUR (w/o VAT)
A9Z05225
Code: A9Z05225
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

24.70 EUR (w/o VAT)
A9R41425
Code: A9R41425
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

60.43 EUR (w/o VAT)
AR056103
Code: AR056103
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

56.48 EUR (w/o VAT)
A9R41225
Code: A9R41225
On site: 0 gab On site: 0 gab

Supplier: 5+ gab

42.67 EUR (w/o VAT)

RCCB and RCBO residual current circuit breakers — Schneider Electric Acti9, stocked in Riga

An RCCB continuously monitors the current balance between the live and neutral conductors. Under normal conditions, every ampere leaving through the live wire returns through the neutral — the two values are equal. When a fault occurs — a person contacts a live part, cable insulation fails, or moisture compromises an appliance — some current finds an alternative path to earth, creating an imbalance. When this imbalance reaches the device's trip threshold (typically 30 mA), the RCCB disconnects the circuit in milliseconds, before a potentially lethal shock can develop.

Unlike a miniature circuit breaker (MCB), an RCCB does not respond to overload or short-circuit current — it must always be used in series with an MCB, or replaced by an RCBO which combines both functions.

RCCB vs RCBO — which to specify?

RCCB

RCBO

Earth leakage protection

Overload protection

Short-circuit protection

Module width (typical)

2–4 modules

1–2 modules

Best for

Protecting groups of circuits

Per-circuit protection; space saving

Recommended

Extending existing installations

New build and refurbishment projects

RCCB and RCBO types — AC, A, B and selective

The type designation defines which categories of leakage current the device can detect:

  • Type AC — detects sinusoidal AC leakage only. Now obsolete; prohibited in new installations in most European countries

  • Type A — detects AC and pulsating DC leakage. The current standard for modern installations with inverter-driven appliances, heat pumps, washing machines and EV wallboxes on dedicated circuits

  • Type B — detects AC, pulsating DC and smooth DC leakage. Mandatory for EV charging stations, photovoltaic inverters, variable frequency drives and other power electronics that can produce smooth DC fault currents

  • Type S (selective) — incorporates a time delay to allow downstream devices to trip first; used in main distribution boards as part of a coordinated protection scheme

Sensitivity ratings and applications

Sensitivity

Primary function

Typical application

10 mA

Personal protection — high sensitivity

Medical locations, wet rooms, children's areas

30 mA

Personal protection — standard

Residential, offices, socket outlet circuits

100 mA

Fire prevention

Commercial lighting, fixed equipment

300 mA

Fire prevention — main distribution

Industrial distribution boards, main incomer protection

Schneider Electric Acti9 — available from stock

The Acti9 platform is Schneider Electric's modular protection range for residential, commercial and light industrial distribution boards. RCBOs combine the benefits of an MCB and an RCD in one compact device, saving installation time and space. The Acti9 iID (RCCB) and iDPN Vigi / iC60 Vigi (RCBO) families cover the full range of current ratings, sensitivity levels and types required for IEC 61008 and IEC 61009 compliant installations. Festo

Selection checklist

Before specifying, confirm:

  • Number of poles — 2P for single-phase, 4P for three-phase circuits

  • Rated current — 16, 25, 40 or 63 A (higher ratings available)

  • Sensitivity — 10, 30, 100 or 300 mA depending on protection function

  • Type — Type A for standard loads; Type B for EV chargers, PV inverters and VFDs

  • Device function — standalone RCCB (paired with existing MCB) or RCBO (combined in one module)

  • Selectivity — whether a time-delayed upstream device is required for coordination

Not sure which configuration to specify? Our engineers can assist with device selection, cross-referencing, and panel coordination for your project.

Typical applications

  • Residential and commercial distribution boards — socket outlet and lighting circuit protection

  • Industrial control panels — earth leakage protection for motor and process circuits

  • EV charging installations — Type B RCCB or RCBO as required by IEC 60364-7-722

  • Photovoltaic and solar installations — Type B protection for inverter output circuits

  • Outdoor and wet area installations — garages, garden supply points, construction sites

  • Main distribution boards — selective 100/300 mA upstream protection for coordinated tripping

What is the difference between an RCCB and an RCBO?

An RCCB provides earth leakage protection only — it will not trip on overload or short-circuit current and must be used in series with an MCB. An RCBO combines both functions in a single DIN rail module, providing per-circuit earth leakage, overload and short-circuit protection independently. RCBOs are the preferred choice for new installations where panel space and fault isolation per circuit are priorities.

Which type of RCCB or RCBO should I specify — Type A or Type B?

Type A is the current standard for most modern installations and handles AC and pulsating DC leakage from inverter-driven appliances, heat pumps and washing machines. Type B is required wherever smooth DC fault currents may occur — EV charging stations, photovoltaic inverters, variable frequency drives and three-phase rectifier equipment. Type AC is no longer recommended for new installations in most European markets.

Why specify 30 mA rather than 300 mA?

30 mA is the international standard for personal protection against electric shock — it is the maximum current that can be tolerated before serious physiological effects occur, and a compliant 30 mA device will disconnect within 300 ms at rated current. 300 mA devices are used for fire prevention at the main incomer level, where a lower sensitivity threshold would cause nuisance tripping from normal operational leakage across large installations.

Does an RCCB protect against short circuits?

No. An RCCB only measures the imbalance between live and neutral current — it does not respond to overload or short-circuit fault current. For complete protection, an RCCB must be used in combination with an MCB sized to the circuit, or the combination replaced by an RCBO which provides both functions in a single device.