RVD260-A district heating controller, Siemens, S55370-C129

Multifunctional heating controller for use in district heating substations and district heating plants with LPB and M-bus communication. Suited for 2 heating circuits with d.h.w. heating in instantaneous systems or with storage tank. 14 programmed plant types. Operating voltage AC 230 V. Same functionality as RVD250 but with the following extra features: - 2 heating circuits - Without precontrol in interconnected systems - 3 independent switching programs each with 3 occupancy times per day Plant-specific: - Precontrol internal control loops - 2 heating circuits (mixing and / or pump heating circuit): Control of flow temperature optionally weather-compensated / weather- and room temperature-compensated / room temperature-compensated - D.h.w. heating with selectable priority: - Instantaneous systems - Storage charging system - Storage system with integrated heat exchanger - Charging pump - Circulating pump

Manufacturer code: S55370-C129

Code: S55370-C129

Manufacturer: SIEMENS

Without VAT With VAT
Buying
1096.01 EUR 1

Need quote?

Available Location Get

0 pcs

ZTF Lāsma Office
Supplier's warehouse Need to clarify
Pick up in the office
The time will be specified after order confirmation.
Delivery to address
The time will be specified after order confirmation.
Omniva
Omniva
Need to clarify

Specification

Code: S55370-C129

Description

Multifunctional heating controller for use in district heating substations and district heating plants with LPB and M-bus communication. Suited for 2 heating circuits with d.h.w. heating in instantaneous systems or with storage tank. 14 programmed plant types. Operating voltage AC 230 V. Same functionality as RVD250 but with the following extra features: - 2 heating circuits - Without precontrol in interconnected systems - 3 independent switching programs each with 3 occupancy times per day Plant-specific: - Precontrol internal control loops - 2 heating circuits (mixing and / or pump heating circuit): Control of flow temperature optionally weather-compensated / weather- and room temperature-compensated / room temperature-compensated - D.h.w. heating with selectable priority: - Instantaneous systems - Storage charging system - Storage system with integrated heat exchanger - Charging pump - Circulating pump

Ask a question

If you have any questions about the product, please enter them in the field below.

Our team will make sure to provide you with the necessary answers as soon as possible!

I agree with personal data proccessing
I agree to receive notifications from lasma.eu by email.