- Sensor for measuring wind speed, measuring range 2-30 m/s - Three independent brightness sensors, measuring range 1-100 k Lux - Consideration of up to two external brightness sensors - Outdoor temperature sensor, measuring range -30 … +60°C - Transmission of all measurement readings via the bus - Monitoring of all measurement readings - Consideration of the alignment of up to 3 facades and automatic activation / deactivation of the solar protection of a facade during the time in which the sun shines on the respective facade - Safety alarm for deactivating the solar protection, initiated by an external safety object or by logical AND/ OR operations of the measured weather data - 4 threshold switches, independant of the weather data, each with 2 output objects - 6 logical AND, OR or XOR operations, independant of the whether data, of respectively up to 4 input objects and each with 2 output objects - Integrated bus coupling unit, bus connection via a bus terminal block - As a compact unit for mast or wall mounting, including mast fixture for diameter 48-60 mm
|
Without VAT
With VAT
|
Buying |
|---|---|
| 444.00 EUR | 1 |
Need quote?
| Available | Location | Get |
|---|---|---|
|
0 pcs |
ZTF Lāsma Office | |
|
Ask about availability
|
Supplier's warehouse | Need to clarify |
|
Pick up in the office
The time will be specified after order confirmation.
|
|
|
Delivery to address
The time will be specified after order confirmation.
|
|
|
|
Omniva
Need to clarify
|
| Code: | 5WG1257-3AB51 |
|---|
- Sensor for measuring wind speed, measuring range 2-30 m/s - Three independent brightness sensors, measuring range 1-100 k Lux - Consideration of up to two external brightness sensors - Outdoor temperature sensor, measuring range -30 … +60°C - Transmission of all measurement readings via the bus - Monitoring of all measurement readings - Consideration of the alignment of up to 3 facades and automatic activation / deactivation of the solar protection of a facade during the time in which the sun shines on the respective facade - Safety alarm for deactivating the solar protection, initiated by an external safety object or by logical AND/ OR operations of the measured weather data - 4 threshold switches, independant of the weather data, each with 2 output objects - 6 logical AND, OR or XOR operations, independant of the whether data, of respectively up to 4 input objects and each with 2 output objects - Integrated bus coupling unit, bus connection via a bus terminal block - As a compact unit for mast or wall mounting, including mast fixture for diameter 48-60 mm
If you have any questions about the product, please enter them in the field below.