Multifunctional heating controller for use in district heating substations and district heating plants with LPB and M-bus communication. Suited for one heating circuit with d.h.w. heating in instantaneous systems or with storage tank. 28 programmed plant types. Operating voltage AC 230 V. Key features: - Optimized for low return temperatures in district heating networks. - Display of time of day time program setpoints actual values limitations errors etc. - Optional remote operation via room unit - 2 independent switching programs each with 3 occupancy times per day - Yearly clock with automatic summer- / wintertime changeover - Power and / or volumetric flow limitation in combination with heat meter - Pump and valve protection - Automatic monitoring of sensors with display of alarm - Locking function for district heat parameters - Optional suppression of hydraulic creep - Frost protection function - DRT limitation for the reduction of peak loads and of idle heat - Maximum limitation of the return temperature on the primary side - Minimum and maximum limitation of the flow temperature - Optimum start / stop control of the heating system - Automatic ECO function - Legionella function - Forced charging function for plant with storage tank - Cooling down protection for the primary supply lines - Solar d.h.w. heating - D.h.w. heating with electric immersion heater - Refill function - Selectable heating period Plant-specific: - Precontrol internal and interconnected - 1 mixing or pump heating circuit - D.h.w. heating with selectable priority: - Instantaneous systems - Storage charging system - Storage system with integrated heat exchanger - Circulating pump, 2 charging pump -
|
Without VAT
With VAT
|
Buying |
|---|---|
| 989.33 EUR | 1 |
Need quote?
| Available | Location | Get |
|---|---|---|
|
0 pcs |
ZTF Lāsma Office | |
|
Ask about availability
|
Supplier's warehouse | Need to clarify |
|
Pick up in the office
The time will be specified after order confirmation.
|
|
|
Delivery to address
The time will be specified after order confirmation.
|
|
|
|
Omniva
Need to clarify
|
| Code: | S55370-C125 |
|---|
Multifunctional heating controller for use in district heating substations and district heating plants with LPB and M-bus communication. Suited for one heating circuit with d.h.w. heating in instantaneous systems or with storage tank. 28 programmed plant types. Operating voltage AC 230 V. Key features: - Optimized for low return temperatures in district heating networks. - Display of time of day time program setpoints actual values limitations errors etc. - Optional remote operation via room unit - 2 independent switching programs each with 3 occupancy times per day - Yearly clock with automatic summer- / wintertime changeover - Power and / or volumetric flow limitation in combination with heat meter - Pump and valve protection - Automatic monitoring of sensors with display of alarm - Locking function for district heat parameters - Optional suppression of hydraulic creep - Frost protection function - DRT limitation for the reduction of peak loads and of idle heat - Maximum limitation of the return temperature on the primary side - Minimum and maximum limitation of the flow temperature - Optimum start / stop control of the heating system - Automatic ECO function - Legionella function - Forced charging function for plant with storage tank - Cooling down protection for the primary supply lines - Solar d.h.w. heating - D.h.w. heating with electric immersion heater - Refill function - Selectable heating period Plant-specific: - Precontrol internal and interconnected - 1 mixing or pump heating circuit - D.h.w. heating with selectable priority: - Instantaneous systems - Storage charging system - Storage system with integrated heat exchanger - Circulating pump, 2 charging pump -
If you have any questions about the product, please enter them in the field below.
Our team will make sure to provide you with the necessary answers as soon as possible!