- KNX communications - Output DC 0…10 V for VAV actuator and auxiliary output ON/OFF, PWM or 3-position or 3-position for VAV actuator and auxiliary output DC 0...10 V - 2 multifunctional inputs for keycard contact, external room / return air temperature (1x, QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector - 1 input DC 0...10 V for damper position feedback, for CO2 sensor - Operating modes: Comfort, Economy and Protection - Modulating PI control - Control depending on the room or the return air temperature and air quality - Automatic or manual heating / cooling changeover - Adjustable commissioning and control parameters - Minimum and maximum setpoint limitation - Minimum and maximum limitation of air flow signal - Output signal inversion (DC 0...10 V) as an option - Backlit display Application selectable: - Single-duct system - Single-duct system with electrical heater - Single-duct system and radiator / floor heating - Single-duct system with heating / cooling coil
|
Without VAT
With VAT
|
Buying |
|---|---|
| 365.42 EUR | 1 |
Need quote?
| Available | Location | Get |
|---|---|---|
|
0 pcs |
ZTF Lāsma Office | |
|
Ask about availability
|
Supplier's warehouse | Need to clarify |
|
Pick up in the office
The time will be specified after order confirmation.
|
|
|
Delivery to address
The time will be specified after order confirmation.
|
|
|
|
Omniva
Need to clarify
|
| Code: | S55770-T348 |
|---|
- KNX communications - Output DC 0…10 V for VAV actuator and auxiliary output ON/OFF, PWM or 3-position or 3-position for VAV actuator and auxiliary output DC 0...10 V - 2 multifunctional inputs for keycard contact, external room / return air temperature (1x, QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector - 1 input DC 0...10 V for damper position feedback, for CO2 sensor - Operating modes: Comfort, Economy and Protection - Modulating PI control - Control depending on the room or the return air temperature and air quality - Automatic or manual heating / cooling changeover - Adjustable commissioning and control parameters - Minimum and maximum setpoint limitation - Minimum and maximum limitation of air flow signal - Output signal inversion (DC 0...10 V) as an option - Backlit display Application selectable: - Single-duct system - Single-duct system with electrical heater - Single-duct system and radiator / floor heating - Single-duct system with heating / cooling coil
If you have any questions about the product, please enter them in the field below.
Our team will make sure to provide you with the necessary answers as soon as possible!