- With emergency lighting, with sensors - For communication via KNX with electronic ballasts (ECG) with a DALI interface - DALI output with DALI-2 certification acc. to IEC 62386-101 and -103, for communication with up to 64 DALI ECG Ed.1 and DALI-2 and at least 10 (from which max. 8 movement detectors) DALI sensors (currently only Osram and Siemens DALI sensors are supported) - Integrated power supply with input voltage AC 110-240 V, 50-60 Hz or DC 120-240 V for powering the gateway electronics and DALI output - Maximum DALI output voltage of 19 V, short circuit resistant - Incorrect voltage detection during commissioning if incorrect power line is connected to a DALI output - LED display for displaying operation mode and error messages - Pushbutton for switching between bus and direct operating mode - One pair of pushbuttons for switching On/Off of all connected DALI ECG - One LED per DALI output for status signal of all connected luminaries in direct mode - Configurable behaviour for bus failure (stand-alone mode) - Configurable pre-loaded applications without software ETS - Scheduler for day, week, date with astro function - Control of all connected luminaries together in broadcast mode - Status signal and display of lamp and ECG failure per group and per DALI device - Transformation of dimming commands into a temporary setpoint adjustment for ECG with integrated constant light level control and directly connected light level sensor - One or two level timer - Up to 4 integrated one time or cyclical control of repeatable sequences or color effects - Distinction between self-contained emergency luminaries with one or two DALI devices - Starting the self-conducted testing of each individual inverter and reporting the test result via bus or save in a persistent memory with memory space monitoring over object - Per channel up to 6 stand-by-area analysis for activation of switch actuators - Scene control for up to 16 scenes per channel - 16 integrated 2-level-controller for brightness control and 16 constant light level controller for main luminaries group and up to 4 additional luminaries groups - Assignment of a CIN to a DALI ECG - Reintegration defective DALI ECG without ETS - Assignment of DALI ECG to groups and test option for ECG, groups, scenes and effects via ETS - Assignment of DALI sensors and test option of sensors via ETS - Integrated bus coupling unit with only half a standard bus load, bus connection via bus terminal - Mounting on DIN rail EN 60715-TH35-7.5
|
Without VAT
With VAT
|
Buying |
|---|---|
| 657.00 EUR | 1 |
Need quote?
| Available | Location | Get |
|---|---|---|
|
0 pcs |
ZTF Lāsma Office | |
|
Ask about availability
|
Supplier's warehouse | Need to clarify |
|
Pick up in the office
The time will be specified after order confirmation.
|
|
|
Delivery to address
The time will be specified after order confirmation.
|
|
|
|
Omniva
Need to clarify
|
| Code: | 5WG1141-1AB03 |
|---|
- With emergency lighting, with sensors - For communication via KNX with electronic ballasts (ECG) with a DALI interface - DALI output with DALI-2 certification acc. to IEC 62386-101 and -103, for communication with up to 64 DALI ECG Ed.1 and DALI-2 and at least 10 (from which max. 8 movement detectors) DALI sensors (currently only Osram and Siemens DALI sensors are supported) - Integrated power supply with input voltage AC 110-240 V, 50-60 Hz or DC 120-240 V for powering the gateway electronics and DALI output - Maximum DALI output voltage of 19 V, short circuit resistant - Incorrect voltage detection during commissioning if incorrect power line is connected to a DALI output - LED display for displaying operation mode and error messages - Pushbutton for switching between bus and direct operating mode - One pair of pushbuttons for switching On/Off of all connected DALI ECG - One LED per DALI output for status signal of all connected luminaries in direct mode - Configurable behaviour for bus failure (stand-alone mode) - Configurable pre-loaded applications without software ETS - Scheduler for day, week, date with astro function - Control of all connected luminaries together in broadcast mode - Status signal and display of lamp and ECG failure per group and per DALI device - Transformation of dimming commands into a temporary setpoint adjustment for ECG with integrated constant light level control and directly connected light level sensor - One or two level timer - Up to 4 integrated one time or cyclical control of repeatable sequences or color effects - Distinction between self-contained emergency luminaries with one or two DALI devices - Starting the self-conducted testing of each individual inverter and reporting the test result via bus or save in a persistent memory with memory space monitoring over object - Per channel up to 6 stand-by-area analysis for activation of switch actuators - Scene control for up to 16 scenes per channel - 16 integrated 2-level-controller for brightness control and 16 constant light level controller for main luminaries group and up to 4 additional luminaries groups - Assignment of a CIN to a DALI ECG - Reintegration defective DALI ECG without ETS - Assignment of DALI ECG to groups and test option for ECG, groups, scenes and effects via ETS - Assignment of DALI sensors and test option of sensors via ETS - Integrated bus coupling unit with only half a standard bus load, bus connection via bus terminal - Mounting on DIN rail EN 60715-TH35-7.5
If you have any questions about the product, please enter them in the field below.
Our team will make sure to provide you with the necessary answers as soon as possible!